MaxCS 7.5 Administration Manual 399
Figure 233. Signaling Layer
6. In the E1 Channel Configuration dialog box, configure the following fields:
Set Calling Party Category to – the Calling Party Category indicates the type of calling party, (for
example, operator, pay phone, priority, ordinary subscriber). Select 1, 2 or 3 (for ordinary subscribers,
refer to Table on page 400). If the subscribed line is intended for other purposes, contact your CO for
the proper value.
Add extra digits before caller ID – consult your CO to find out if any extra digits are needed.
Incoming sequences – select check box and configure the sequence according to Table on page
400.
In-call signaling – configure the in-call signaling value according to Table on page 400.
The circled fields in Figure 233 represent values that depend on your country and its corresponding trunk
property.
Note: Consult your CO to find out if caller ID digits are provided in the lines.