MAXCS 7.0 Update 1MultiVoIP Configuration Guide Page 15 of 27
• Set Caller ID Type to BellCore
• Check the Caller ID Enable check box
4. Select Configuration > Interface.
5. Click the Supervision button and set the following parameters:
• Check the Answer Delay checkbox
• Set Answer Delay Timer to 1
6. These settings only apply to Channel 3. Apply these setting to other FXO channels, if there are
others.
7. Select Save Setup > Save & Reboot, click OK. Wait for the gateway to reboot itself.
Verification
1. Follow Figure 2 and attach the PSTN line 510-252-0001 to FXO/FXS Channel 3 behind the MVP
gateway.
Important! Attach the line to FXS/FXO port instead of the E&M port.
2. Place a PSTN call from an outside line (for instance, from your cell phone) to 510-252-0001. The
call should be sent to MaxCS through the MVP gateway.
3. Apply the same settings to Channel 4 on the MVP gateway. Attach the PSTN line 510-252-0002 to
FXO/FXS Channel 4 behind the gateway.
SIP-Tie Trunk Configuration for Outgoing Calls to PSTN
Before configuring these SIP-tie trunks, the requirements in the section Requirements must be met, and
the steps in the section
SIP-Tie Trunk Configuration for Incoming Calls from PSTN must to be completed.
Comentarios a estos manuales