CDR Data Schema
378 AltiWare OE System Installation & Administration Manual
TargetType Type of line for an
outgoing call
UBYTE 0=None
1=Ext analog
2=Ext IP
3=Ext PHS (not
used)
4=Ext virtual
5=Ext WG
11=trk analog
12=trk T1
13=trk IP
14=trk PRI
15=trk PHS (not
used)
TargetPad Physical address of
line for an outgoing
call
UCHAR
(5)
E.g. “0004,”
where “00”=slot
and
“04”=channel
TargetNum Target phone number
of an outgoing call
(extension number or
off-net PSTN)
UCHAR
(41)
TargetName Target name for an
outgoing call (as
entered in AltiAdmin
for extension calls)
UCHAR
(65)
WGNum Workgroup number
for an incoming call
UCHAR
(8)
OutGoingWG Workgroup number
foran outgoing call, as
set in AltiAdmin or by
agent at logon
UCHAR
(8)
DNIS DNIS number for
incoming call
UCHAR
(33)
Table 1: CDR Call Format
Database
Element
Definition Type Specification