Altigen ACM 6.5 Guía de usuario Pagina 364

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 502
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 363
Defining IP Networks
350 MAXCS ACM 6.5 Administration Manual
Note: When MAXCS is behind a NAT router, and you do not check the Private Network
check box, IP phones may not function.
To define an address range
1. Click the Add button in the IP Network panel. The Add IP Network dialog box
appears.
2. Fill in a range of IP addresses.
3. Select the pipe for this IP address range.
4. If this is a private network, check the Private Network check box.
5. Click OK.
To edit a network you’ve added, select it and click the Edit button. To remove it, select
it and click the Remove button.
Configuring a Public or Intranet Pipe
If you want to regulate how many VoIP sessions can be connected to the server through
a Public or Intranet Pipe,
1. In the Public Pipe panel, check the Enable box.
2. Enter the maximum WAN bandwidth you want to allocate to VoIP connections. The
system will calculate the maximum sessions for each type of codec automatically.
3. You can change the G.711 sessions by using the Up/Down arrow button.
Notes
When calculating the maximum sessions for each codec, the system uses the
following bandwidth requirement to ensure that each session has some safety
margin:
G.711 - 90 kbps
Vista de pagina 363