Board Configuration
AltiContact Manager Administration Manual 6-17
6. Board
Configuration
Triton T1 Configuration - Triton T1/PRI Dialog Box
Double clicking the span line for a Triton T1 board in the Span Info
window invokes a T1/PRI Configuration dialog box.
Figure 9. Triton T1/PRI Configuration dialog box
Reading the Status Messages
If the span is working, the Status line displays OK. This status line is
updated every 3 seconds. If there is an error, a message is displayed. The
following table lists the types of error messages and the appropriate actions.
Table 1: Span Status Error Messages
Error Message Meaning Action
Hardware Failure - NO
ANSWER
Major hardware prob-
lem. Board is not
responding to com-
mands.
Set board as MVIP
master. Reset Board.