2-6 AltiContact Manager Administration Manual
MVIP Compatible
256 Port Non-Blocking Switch Matrix
Jumper-Free Configuration
PCI Bus
Compliant with EIA464
Recording capability
Note: When the board is configured for audio input, the first port cannot
be used for an extension.
Triton Analog Trunk Board
The Triton Analog Trunk board comes in two models: Loop Start/Ground
Start (LS/GS) and Loop Start only (LS). It supports 12 analog trunks and
offers FSK Caller ID receiving, Centrex flash, and voice/silence activated
answer supervision. This board is also compatible with major PCI chassis
vendors.
The Triton Analog Trunk board has the following functional
characteristics:
MVIP-compatible
256 Port Non-Blocking Switch Matrix
Jumper-Free Configuration
32-bit, 5v PCI Bus
Compliant with EIA464
LS/GS LED Indicators* LS LED Indicators
LED 1B LED 1A Status LED 1B LED 1A Status
ON ON Normal ON ON Normal
OFF OFF No power to board OFF OFF No +5V or less than
4.1V
ON OFF No +5V or less than
4.1V
OFF ON No +12V or less than
9.2V
*
LED 2, located on the board, is a red LED for
diagnostic purposes. If it is ON, the fuse is blown.